CloudEngine data center storage network switches adopt advanced hardware structures and have high-density 10/25/50/100GE downlink ports and 100/200/400GE uplink ports, providing high performance, high reliability, and low downtime for all-flash storage data centers. Delay, easy operation and maintenance and other characteristics. While the air flow direction can be flexibly adjusted, it can adapt to any computer room layout. The unique lossless algorithm makes NVMe non-volatile memory (NVMe) more efficient and fully unleashes the value of all-flash storage. In addition, NVMe Over Fabric+ (NOF+) enables plug-and-play of storage systems and end-to-end (E2E) visibility of link and network performance.
Technical specifications
参数CloudEngine 6885-SAN-56FCloudEngine 6860-SAN CloudEngine 8850-SAN 
下行链路端口224个10GE SFP+/25GE SFP28端口或48个10GE SFP+/25GE SFP28端口或48个50GE SFP56端口24个10GE SFP+/25GE SFP28端口或48个10GE SFP+/25GE SFP28端口或48个50GE SFP56端口32个40GE QSFP+/100GE QSFP28端口或32个200GE QSFP56端口
上行链路端口28 个 100 GE QSFP28 端口或 8 个 200 GE QSFP56 端口8 个 100 GE QSFP28 端口或 8 个 200 GE QSFP56 端口8 个 400 GE QSFP-DD
交换容量8 Tbit/秒8 Tbit/秒19.2 Tbit/秒
转发速率1200 英里/秒2400英里/秒7200英里/秒
缓冲区64兆字节64兆字节64兆字节
可靠性用于 BGP、IS-IS、OSPF、静态路由和 VXLAN
的 LACP
BFD 基于硬件的 BFD
DPFR
MoFRR
用于 BGP、IS-IS、OSPF、静态路由和 VXLAN
基于硬件的 BFD 的 LACP
BFD
运维遥测
Netstream
ERSPAN+
IFIT
数据包事件
1588v2
遥测
Netstream
ERSPAN+
IOAM
AnyFlow
智能流量分析

数据中心功能1588v2
MACsec
VXLAN 路由和桥接
BGP EVPN
M-LAG
PFC、AI ECN
VXLAN 路由和桥接
BGP EVPN
M-LAG
智能无损网络AI ECN PFC 死锁预防
iNOF
NPCC(基于网络的主动拥塞控制) ECN Overlay
iQCN
(智能量化拥塞通知)
最大功耗48 x 25G + 8 x 100G:200W(100%流量负载,全端口短距离光模块,常温,双交流电源模块) 326W(100%流量负载,所有端口长距离光模块,高温,双交流电源模块)
48 x 50G + 8 x 200G:227 W(100% 流量负载,48 x 50G 端口上的铜缆, 8个200G端口短距离光模块,常温,双交流电源模块) 328W(100%流量负载,48个50G端口铜缆,8个200G端口长距离光模块,高温,双交流电源模块)
48 x 50 GE + 8 x 200 GE:619 W(100%流量负载,所有下行端口均配备2 W 50GE光模块,所有上行端口均配备6.5 W 200GE光模块,40°C,双电源模块)
48 x 25GE + 8 x 100GE:544W(100%流量负载,所有下行端口均配备1.5W 25GE光模块, 所有上行端口均带5W 100GE光模块,40°C,双电源模块)
32×200GE+8×400GE:1152W(100%流量负载,下行端口均采用2W50GE光模块,上行端口均采用6.5W200GE光模块,40°C,双电源模块)
32×100GE+8×400GE:973W(100%流量负载,所有下行端口均采用1.5W25GE光模块, 所有上行端口均带5W 100GE光模块,40°C,双电源模块)
电源600 瓦交流电和 240 伏直流电 1200 瓦直流
600 W 交流电和 240 V 直流电、1200 W 交流电和 240 V 直流电、1000 W –48 V 直流电、1200 瓦高压直流


1200 W 交流电
工作电压交流:90V至290V;HVDC:190V~290V 直流:-48V:-38.4V至-72V
;+48V 直流:+38.4V 至 +60V
交流电:90–290V
重构件:240V (188–288V) 380V (188–400V)

直流:–38.4V 至 –72V
交流电:90–290 V

1  CloudEngine 6860-SAN加载CE68-RTU-U24S和CE68-RTU-U8CQ硬件RTU授权后,可提供48个50GE端口和8个200GE端口。CloudEngine 8850-SAN默认仅支持32个100GE端口。升级至32个200GE端口,购买CE88-RTU-U32CQ硬件RTU。如需使用8个400GE QSFPDD端口,请购买CE88-RTU-8DQ硬件RTU。